GC112N Gas Chromatograph With Software

GC112N Gas Chromatograph With Software
Gas chromatograph is one of several analytical instruments with a wide range of applications. It has become an ideal analytical instrument for separation or analysis in various fields such as petrochemicals, environmental protection, food safety, medicine and health, national defense, legal inspection, and ultra-pure materials.
  • ModelGC112N
  • MerkLABOAO
  • HavenAny port in China
  • PakketPlywood case package
Betaling We ondersteunen ook L/C、D/A、D/P、Western Union、MoneyGram、Ontdek betalingen voor offline bestellingen.

DESCRIPTION

GC112N comes with PC-side reverse control software and built-in chromatography workstation, which can realize PC-side reverse control and host touch screen synchronous bidirectional control. It is equipped with an automatic sampler installation positioning interface, which can match various specifications of automatic samplers. The multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument. The use of logarithmic amplifier, the detection signal has no cutoff value, the peak shape is good, and the scalable synchronous external trigger function can be used to start the host and workstation at the same time by external signals (automatic sampler, thermal analyzer, etc.). 

FEATURES

1. Standard PC control software, built-in chromatographic workstation, achieve PC side reverse control and touch screen synchronous bidirectional control. 
2. 7-inch color touch screen, carrier/hydrogen/air channel flow (pressure) digital display.
3. Gas shortage alarm protection function; Heating control protection function (when opening the door of the column box, the motor of the column box fan and the heating system will shut down automatically).
4. Split flow/split ratio can be automatically controlled to save carrier gas.
5. Configure automatic sampler installation and positioning interface to match automatic sampler of various specifications.
6. The multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument.
7. One-button start function, with 20 groups of sample test mode memory function.
8. Using logarithmic amplifier, detection signal no cut-off value, good peak shape, extensible synchronous external trigger function, can be started by external signals (automatic sampler, thermal analyzer, etc.) at the same time the host and workstation.
9. It has perfect system self-check function and fault automatic identification function.
10.With 8 external event extension function interface, can be selected with various function control valves, and according to their own set time sequence work.
11. RS232 communication port and LAM network port, and the configuration of data acquisition card.

SPECIFICATIONS

Model

GC112N

Oven

Content   product: 22L

Temperature   control range: 5   ~ 400   at room temperature

Temperature   control accuracy: ±0.1

Heating   rate: 0.1 ~ 60   / min

Program   temperature rise order: 9

Program   heating repeatability: 2%

Cooling way:   open the door after

Cooling   speed: 10   mins (250   ~ 50)

Control   software function

Column   temperature box control

Detector   control

Injector   control

Map display

Sampler   Injector

Temperature   control range: 7   ~ 420   at room temperature

Temperature   control method: independent temperature control

Carrier gas   flow control mode: constant pressure

Number of   simultaneous installations: 3 at most

Type of   injection unit: filling column, shunt

Split ratio:   split ratio display

Cylinder   pressure range: 0 ~ 400kPa

Cylinder   pressure control accuracy: 0.1kPa

Flow setting   range: H2 0 ~ 200ml / min    N2 0 ~   150ml / min

Detector

FID, TCD   (optional)

Temperature   control: Max. 420

Number of   simultaneous installations: 2 at most

Ignition   function: automatic

Hydrogen   flame ionization detector (FID)

Detection   limit:   3×10-12   g/s (n-hexadecane)

Baseline   noise:   5×   10-14A

Baseline   drift:   6×   10-13A

Dynamic range:   107

RSD: 3% or   less

Supply   voltage: AC220V±22V,   50Hz±0.5Hz

Power: 3000W

Optional

Thermal   conductivity detector (TCD)

Sensitivity:   5000mVmL/mg   (n-cetane)

Baseline   noise:   0.05 mV

Baseline   drift:   0.15mV / 30min

Dynamic range:   105

Packed   column

Capillary   column

WAAROM VOOR ONS KIEZEN

  1. Directe verkoop in de fabriek met een concurrerende prijs.
  2. Premiumkwaliteit met CE- en ISO-certificering.
  3. Sterke OEM- en ODM-aanpassingsmogelijkheden voor producten.
  4. Beloof productie en tijdige levering.
  5. Perfecte klantenservice, gratis productaccessoires.
  6. 15 jaar ervaring in R&D en productie van gas chromatography(gc) machine.
laboao certification

ONZE FABRIEK

We hebben een standaard productiewerkplaats en een compleet productieteam. Ze produceren altijd een serieuze en verantwoordelijke houding om elk product te produceren. Ons R & D-team bestaat uit professionele ingenieurs met meerdere aspecten, zoals ontwerpingenieur, technologiespecialist, gekwalificeerde specialist en procescontrolemanager, enz. Onze gekwalificeerde specialisten realiseren strikt het uitgebreide procestoezicht op basis van ons kwaliteitsprocescontrolesysteem, dat het ontwerp van producten bevat , onderzoek en ontwikkeling, testen, productie, kwaliteitsinspectie en verpakking.

laboao factory

KLANTGEVALLEN

Onze laboratoriuminstrumenten en -apparatuur worden gebruikt in veel wetenschappelijke laboratoria, wetenschappelijke onderzoeksinstellingen, universiteiten, ziekenhuizen, centra voor ziektebestrijding en andere instellingen, en worden gecombineerd met vele bekende biofarmaceutica, nieuwe energie, elektronicabedrijven, voedselverwerking, milieubescherming, enz. Samenwerking tussen bedrijven, onze stabiele en betrouwbare producten worden geëxporteerd naar meer dan 120 landen over de hele wereld en worden door hen zeer erkend, geloof LABOAO, we groeien samen!

laboao customer cases

Vraag dit product aan